Superior Epoxies & Coatings, Inc.
Superior Products For Your Superior Solution
2527 Lantrac Court - Decatur, GA 30035
Phone: 800-240-1310 - Fax:  800-240-7662
info@superiorepoxies.com



Superior Joint Seal - 80 Non-Sag - Two Component, 100% Solids, Resilient, Floor & Wall Joint Filler

DESCRIPTION:

SUPERIOR JOINT SEAL-80 NON SAG is a two component, 100% solids, equal volume mix, semi-rigid, heavy duty epoxy joint filler for industrial floors and walls.

USES:

Joint filler for industrial concrete floors subjected to hard wheeled vehicles such as forklifts. SUPERIOR JOINT SEAL-80 NON SAG may be used for repairing spills, cracks and damaged joints in floors and walls.

ADVANTAGES:

Easy -to-use 1:1 by volume mix ratio.

Non-sag for vertical application.

Color coded to insure thorough mixing.

Retains resiliency; does not become brittle with age.

Excellent wear resistance.

Semi-rigid support joint edges and to carry heavy loads across the joint.

SURFACE PREPARATION:

Area must be clean and dry. Saw-cuts shall be blown clean and dry with compressed air to remove all excess moisture and debris. Remove curing and sealing compounds.

MIXING AND APPLICATION:

Stir both A and B components before mixing together. Mix equal volumes of Part A and Part B. Mix thoroughly with a heavy duty, low speed drill fitted with a mixing paddle. Mix until a uniform gray color with no streaks is evident. Be sure to scrape the sides and bottom of the mixing pail.

For neat and easy application, tape both sides of joints with masking tape. Apply with bulk caulking gun, disposable plastic dispenser or knife into joint with a spatula or trowel. Fill joints flush to the top or slightly higher than the surrounding surface. Tool joints off flush before SUPERIOR JOINT SEAL-80 NON SAG starts to set. Remove all tape and clean spills and tools immediately upon completion of installation.

 

VOLUME REQUIREMENTS FOR FILLING JOINTS (Linear feet per gallon)

Joint 1/4 ˝ 3/4 1 1 1/4 1 ˝
1/4 306.0 - - - - -
˝ 154.0 77.0 - - - -
3/4 102.7 51.3 34.2 - - -
1 77.0 38.5 25.7 19.3 - -
1 1/4 61.6 30.8 20.5 15.4 12.3 -
1 ˝ 51.3 25.7 17.1 12.8 10.3 8.6
1 3/4 44.0 22.0 14.7 11.0 8.6 7.3
2 38.5 19.3 12.8 9.6 7.7 6.4
2 ˝ 30.8 15.4 10.3 7.7 6.2 5.1
3 25.7 12.8 8.6 6.4 5.1 4.3

LIMITATIONS:

Do NOT apply when temperature is below 50°F.

Do NOT use in true expansion joints, exterior joints, tooled joints, or joints subject to chemical exposure.

Do NOT install in concrete less than 28 days old.

Best results are obtained when applied 3 to 6 months after construction.

Do NOT use compressible backer rod.

CLEAN UP:

Clean tools and equipment immediately with a suitable solvent such as xylene or lacquer thinner.

PACKAGING:

2 gallon units

10 gallon units

CAUTION:

For professional use only. Epoxy systems can cause delayed dermatitis. Avoid prolonged contact with skin. See Material Safety Data Sheet for proper handling and required safety equipment.

PROPERTIES AT 77°F

 
Mix ratio by volume 1:1
Viscosity Thixotropic paste
Color Part A White; Part B Black; Gray mixed
Pot Life (100 Grams) 15-25 minutes
Hardness Shore A (ASTM D-2240) 80 ± 10
Hardness Shore D (ASTM D-2240) 50 ± 5
Tensile Elongation (ASTM D-638) 25%
Tensile Strength (ASTM D-638) 400-600 psi
Compressive Yield (ASTM D-695) 1,530 psi
Initial Cure 6 - 8 hours
Traffic Ready 8 - 12 hours
Shrinkage Nil
Shelf Life 2 years